Dialyzer

Engineered for reliable quality, with design features that help reduce infection risk and prevent accidental needle sticks. Incorporating a PES membrane with excellent biocompatibility and enhanced clearance, JMS offers a wide range of dialyzers to support optimized patient therapy. JMS PES H Series High-flux dialyzer with excellent sieving performance Effectively removes β2-microglobulin while minimizing albumin loss Convenient dry-pack design for easy handling JMS PES L Series Low-flux dialyzer with moderate ultrafiltration performance Convenient dry-pack design for easy handling

Hemopress Single / Twin

The most efficient way of preparing blood components by reducing extensive manual labour and yield high quality blood components. Incorporates with an 8” color LCD touch screen for better control and visibility. High quality clamp designed to ensure tubes are in place during processing and reduces unnecessary errors. Slim profile with stepper motor driven press removes the need of compressor in conventional automated extractor. Strong support for data management via the connection of LAN or data retrieval from USB port. The Benefits: 8” Colour LCD touch screen IR Sensor: For level detection Snap tip: Auto-breaker Stepper motor: Precise press Data Management: Software

NEOSHIELD

The simple design realizes to handle safe and efficient preparation/ administration processes for chemotherapy Preparation Less number of devices achieve easy handling. The risk of exposure to hazardous drugs during operation is reduced. Administration One-touch operation for connection. Priming can be conducted at closed-condition.
Vial Spike  Code: SV-NSMS  Packing: 200 ea per carton  Vial Spike (32mm)  Code: SV-NSMS32  Packing: 250 ea per carton  Lever Lock  Code: SV-NSLL  Packing: 200 ea per carton  Bag Adaptor  Code: SV-NSBA  Packing: 250 ea per carton 
Bag Adapter-ISO  Code: SV-NSBAI  Packing: 250 ea per carton  Plug  Code: SV-NSPG  Packing: 200 ea per carton  Lever Lock Adaptor  Code: SV-NSLLA  Packing: 500 ea per carton   

Single Patient Dialysis Machine

Next generation Dialysis Innovation and safety at your fingertips   Ergonomic, user-focused design ensures safe and smooth operation for all medical professionals Reduced visual strain with a clean, rounded design for greater comfort during use Enhanced visibility through a layout that prevents bloodline crossing Simplified connections with a wide, flat setting area and intuitive, user-friendly design Easy maintenance with optimized shapes and rounded edges for improved cleaning efficiency

Tongue Pressure Monitor

JMS Tongue Pressure Measurement Device is the device to measure the tongue's motor function as the maximum tongue pressure. The measured value can be used as indicators for oral function tests related to the evaluation of feeding and swallowing function, etc. Simple two-button operation: Power and Measure/Reset for ease of use. Large LCD display shows maximum pressure, current pressure, and level indicators in real time, making it easy to track results and provide patient feedback. Complies with CE marking standards for safety and quality assurance.

PECO Panda

PECOPANDA™ is a self-training device designed to strengthen tongue power (tongue pressure), which plays a key role in eating and swallowing. The tongue helps move food within the mouth and guides it safely to the throat—functions that rely on adequate tongue strength. PECOPANDA™ supports targeted training to improve the tongue pressure needed for effective swallowing.

Surgical Gown

Our Quality Standards for surgical gowns are guided by:
  • American Society for Testing and Materials (ASTM) F2407
  • American National Standards Institute (ANSI)
  • Association of the Advancement of Medical Instrumentation (AAMI)
  • European standard EN 13795
The selection and determination are often decided by the hospital OR internal policies. The Infection Control team together with OR management team may collaborate to come up with guidelines and protocol for surgical procedures in the OR. Often gowning procedures are included. In the absence of such guidelines, listed below are some suggestions for the selection of surgical gowns based on AAMI protection standards. AAMI 2 Generally for minor and simple procedures. Sometimes used for dental surgeries too AAMI 3 For most general surgeries that are NOT long duration or involve a lot of fluid AAMI 4 For major surgeries taking long duration and involving much fluid, e.g. knee/hip replacement, cardiovascular, brain etc. Also involving infectious diseases such as hepatitis and HIV

IV ADMINISTRATION SETS

JMS manufactures IV administration sets for both adult Type 200 (Non-Vented): Designed for fluid delivery from flexible bags, or semi-rigid containers and glass bottles when used with an air needle. Type 500 (Vented): Suitable for both rigid containers and flexible bags, featuring an air inlet with a 0.15 µm bacterial filter integrated into the drip chamber.  

SCALP VEIN INFUSION SET

Super thin-wall needle design provides a larger inner diameter for improved flow and smooth infusion. The precision-engineered needle is individually siliconized for enhanced sharpness and reduced discomfort during venipuncture. Features an ergonomic wing design for secure grip and stable fixation. The optimally soft Luer connector ensures a reliable fit with Luer adaptors, 3-way stopcocks, and syringes, with Luer-lock and intermittent configurations available. Equipped with soft, clear, kink-resistant medical-grade PVC tubing for consistent flow and dependable connection. Individually packed in blister or tape using medical-grade materials. Colour-coded in compliance with ISO 6009 for easy gauge identification. Supplied sterile and sterilised using ethylene oxide (ETO) in accordance with EN 550 and ISO 11135 standards.

SAFETY SCALP VEIN

The safety scalp vein set is designed to reduce the risk of accidental needlestick injuries to healthcare professionals. Features an integrated safety sheath with a low-profile design, allowing full retraction and secure encapsulation of the needle tip. Eliminates the need for additional safety accessories. Incorporates a rear-end stopper to help prevent fluid dripping during use.

Safety Scalp Vein Collection Set

  • JMS safety products are designed in accordance with the OSHA pathogens standards
  • Closed system sampling equipped with Luer adaptor and holder with synthetic rubber to avoid blood leakages when changing the vacuum tube during the blood aspiration
  • Attachment with PlanectaTM can be customised for arterial blood collection

Transfusion Set

Designed for the intravenous delivery of blood and blood components, with transfusion set options available with or without needle. Features an ISO 1135-4 compliant spike with a double drip chamber, ensuring accurate and consistent flow control. End connections comply with ISO 594/1 and ISO 594/2 standards, with optional injection sites. Includes a transparent hub for easy observation of flashback and soft, clear, kink-resistant medical-grade tubing for smooth transfusion. Equipped with an 18G super thin-wall needle for improved flow rate and reduced patient discomfort. Available in multiple configurations: Transfusion Set Type 5, Type Y, Buret, and Type Y with Pump.