CPD-SAGM System

The most comprehensive system comprises of CPD anticoagulant solution and SAGM (saline-adenine-glucose-mannitol) additive solution. It has the flexibility to yield high quality blood components such as platelet concentrates, plasma and red blood cells. The system can extend high quality red blood cells up to 42 days while achieving more than 80% of post transfusion RBC survival rate. The Benefits
  • Superior red blood cell viability for 42 days storage with low hemolysis
  • Compatible with most manual and automated component extractors
  • Increases plasma yield
  • Platelet concentrate storage up to 5 days

CPDA-1​

The CPDA-1 blood bag system features a primary bag containing citrate-phosphate-dextrose-adenine anticoagulant, designed for efficient collection and preservation of whole blood. It maintains red blood cell viability for up to 35 days and meets hospital blood bank and transfusion service standards. The Benefits
  • Preserves red blood cells for up to 35 days
  • Maintains low haemolysis during storage
  • Suitable for whole blood storage and component preparation
  • Compatible with standard manual and automated processing systems

In-Line Leuko-Filtration System

Whole Blood In-Line Leukocyte Reduction System Leukocyte reduction in blood component is important to reduce transfusion reactions such as non-hemolytic febrile transfusion reactions, transmission of leukocyte-borne virus, prevention of HLA alloimmunization and platelet refractoriness. Our complete blood bag system for whole blood filtration meets the EU standards and requirements for quality with efficient handling. The Benefits
  • High efficiency Safe and consistent
  • Ease of Use Collection, filtration and storage processes
  • Excellent Quality Meets International requirements
  • Clinically Proven Filtration performance with good efficacy
Red Cell In-Line Leukocyte Reduction System In addition to Whole Blood In-Line Leuko-Filtration System, the Red Cell In-Line Leukocyte Reduction System provides a safe, effective, and convenient preparation of platelets, plasma, and red cells. The system is coupled with high efficient leukoctye filtration that meets EU standards. The Benefits
  • High efficiency Safe & Consistent
  • Excellent Performance Compatible with various processing methods and connecting devices
  • Soft Housing Filter Low breakage of blood bag and ease of handling for centrifugation

Platelets Pooling and Storage System

JMS Leukoreduction for Pooled Platelet and Storage system is carefully designed to fulfil complex needs for platelet concentrates preparation and storage. The system offers flexible pooling options, allowing pooled platelets to be prepared from 4–6 units of whole blood–derived platelet concentrates or buffy coats, combined with 1 unit of plasma or platelet additive solution (PAS). An optional leukocyte-reduction filter can be incorporated prior to storage, ensuring product quality before placement in a highly gas-permeable storage bag.   The Benefits
  • Sterile pooling system with capacity for up to six connectors
  • Integrated high-efficiency leukocyte-reduction filter
  • Highly gas-permeable polyolefin storage bag, supporting storage of up to 7 days*
  • Dedicated sampling bag for convenient laboratory testing
*The maximum storage time for platelets is 5 days, but storage may be extended to 7 days, in conjunction with detection or reduction of bacterial contamination and depending on the type of additive solution (if applicable).

Top & Bottom Extraction System

JMS T-BEX provides great efficiency and productivity in preparing blood components. The system reduces manual labour and increases yield while maintaining high quality blood components prepared from whole blood The Benefits
  • Compatible with most commercial automatic extractors
  • Reduces labour and increases productivity
  • High efficiency component preparation

Transfer Bag

Provides convenience of transferring blood or blood components into multiple units. JMS Transfer Bag can be easily use for separation or distribution of blood components and compatible with most sterile connecting devices. The Benefits
  • Compatible with sterile connecting devices
  • Different bag sizes and volumes
  • ISO Compliance design and performance

Leukocyte Reduction Filter

Sepacell™ filters adopt selective technology combining screen filtration and dept filtration to achieve the highest efficiency. Screen filtration separates particles from solution based on their size, and traps microaggregates. Depth filters are usually composed of densely packed fibers, where particles are excluded either by adherence or by adsorption onto the fibers, or by entrapment between the fibers as they pass through the filter. Whole blood filtration Hard Housing – GLT-H7, GLT-H9 RBC filtration Hard Housing – GLT-A8, GLT-A9, GLT-E9 Soft Housing – Sepacell™ RS2

Safety Scalp Vein Collection Set

  • JMS safety products are designed in accordance with the OSHA pathogens standards
  • Closed system sampling equipped with Luer adaptor and holder with synthetic rubber to avoid blood leakages when changing the vacuum tube during the blood aspiration
  • Attachment with PlanectaTM can be customised for arterial blood collection

Blunt Needle

Designed to follow existing scar-tissue tracks instead of puncturing new skin, minimizing pain and protecting the fistula vessel. The Benefits
  • Buttonhole Bevel – Reduced Pain: Glides through a pre-formed, non-innervated tunnel for minimal discomfort.
  • Cap for safely and aseptically removing buttonhole scabs

Blood Tubing Set

JMS Hemodialysis Tubing Sets are sterilized using either steam or Ethylene Oxide (ETO) sterilization methods to ensure optimal safety and reliability. A Pioneer in Hemodialysis Administration in Japan Backed by extensive experience, technical expertise, and proven product quality Manufactured in compliance with Japan Ministry of Health and Welfare (MHW) requirements, ISO 13485, EN 46001, and CE certification standards Flexible Product Configuration
  • Customizable configurations designed to meet specific user and clinical requirements
Blood Chamber
  • Engineered to minimize foaming during operation
Clamp
  • Ergonomically designed for easy, secure, and reliable handling
Pump Segment
  • Designed for optimal and consistent machine fit, ensuring reliable geometry, occlusion performance, and shore hardness
Dialyzer Connector
  • Universal connector compatible with both Luer-Lock and non-lock type dialyzers
White Recirculation Cap with Cover
  • Vented design facilitates priming
  • Equipped with Luer-Lock connection for recirculation
Injection Ports
  • Latex-free septum with differentiated color coding for ease of identification
  • Needle-free injection port option available

Transfusion Set

Designed for the intravenous delivery of blood and blood components, with transfusion set options available with or without needle. Features an ISO 1135-4 compliant spike with a double drip chamber, ensuring accurate and consistent flow control. End connections comply with ISO 594/1 and ISO 594/2 standards, with optional injection sites. Includes a transparent hub for easy observation of flashback and soft, clear, kink-resistant medical-grade tubing for smooth transfusion. Equipped with an 18G super thin-wall needle for improved flow rate and reduced patient discomfort. Available in multiple configurations: Transfusion Set Type 5, Type Y, Buret, and Type Y with Pump.

EXTENSION TUBE

Designed for extending intravenous lines or connecting to transfusion sets, syringes, syringe pumps, 3-way stopcocks, and other intermittent injection accessories. Available in mini and micro volume extension tubes ranging from 10 to 200 cm, with tube volumes from 0.2 ml to 10 ml to suit different clinical requirements. Features an interchangeable end connector with slip or lock options via the Free Lock mechanism, and a user-friendly male connector with integrated slide-lock design. Reduces the need to stock multiple types of extension or connecting lines.